scientific magazine yafte
مجله علمی پژوهشی یافته
yafte
Medical Sciences
http://yafte.lums.ac.ir
72
journal72
1563-0773
2981-0779
10.18869/acadpub.yafte
en
jalali
1395
9
1
gregorian
2016
12
1
18
3
online
1
fulltext
fa
بررسی غلظت ترکیبات آلی فرار و گازهای آلاینده در مراکز چاپ و تکثیر شهر خرم آباد در سال 1394
Examining the concentrations of volatile organic compounds and pollutant gases in printing and copying centers in Khorramabad, Iran in 2015
پژوهشي
Research
<table align="center" border="0" cellpadding="0" cellspacing="0" dir="rtl" style="width:595px;" width="594">
<tbody>
<tr>
<td style="width:595px;height:22px;">
<p dir="RTL"><strong>مقدمه:</strong> با توجه به تولید آلاینده های گازی و آیروسولی فراوان توسط صنعت چاپ و تکثیر، ارزیابی کیفیت هوا در داخل و خارج این مراکز در سطح شهر خرم آباد مورد بررسی قرار گرفت.</p>
</td>
</tr>
<tr>
<td style="width:595px;height:22px;">
<p dir="RTL"><strong>مواد و روش­ ها: </strong>در یک مطالعه توصیفی، پنج آلاینده گازی از آلاینده های معیار(<span dir="LTR">CO</span>،<span dir="LTR">NO </span>،<span dir="LTR">NO<sub>2 </sub></span>،<span dir="LTR">SO<sub>2 </sub></span><sub> و</sub><span dir="LTR">O<sub>3 </sub></span>) و ترکیبات آلی فرار مورد سنجش قرار گرفت. در کل 360 نمونه از هوای داخل و خارج مراکز چاپ و تکثیر در دو فصل تابستان و زمستان گرفته شد. نمونه برداری به دو روش قرائت مستقیم و نمونه برداری محیطی انجام گرفت. در روش قرائت مستقیم از دستگاه آنالایزر محیطی برای سنجش آلاینده های معیار گازی و از دستگاه <span dir="LTR">phochek5000</span> برای اندازه گیری <span dir="LTR">VOCs</span> استفاده گردید. در نمونه برداری محیطی از پمپ های محیطی و لوله های جاذب کربن فعال <span dir="LTR">SKC</span> به صورت تصادفی-مداوم استفاده گردید. نمونه ها با حلال دی سولفید کربن آماده سازی شدند و با دستگاه کروماتوگراف گازی مورد تجزیه قرار گرفتند. از آزمون آماری <span dir="LTR">t</span> برای آنالیز نتایج استفاده گردید.</p>
</td>
</tr>
<tr>
<td style="width:595px;height:22px;">
<p dir="RTL"><strong>یافته ­ها: </strong>نتایج پژوهش نشان داد که در بین آلاینده های شاخص بجز گاز <span dir="LTR">CO</span> و در بین ترکیبات آلی فرار غلظت آلاینده های بنزن و تولوئن در هوای مراکز چاپ و تکثیر بیشتر از استاندارد <span dir="LTR">EPA</span> برای اماکن بسته می باشد. همچنین بین غلظت بنزن و تولوئن در فصل تابستان و زمستان اختلاف معنی داری وجود داشت (05/0<span dir="LTR">P<</span>). در همه اندازگیری ها در فصول تابستان و زمستان میزان گاز <span dir="LTR">O<sub>3</sub></span> در داخل مراکز چاپ و تکثیر به صورت معناداری بیشتر از فضای آزاد بود (05/0<span dir="LTR">P<</span>).</p>
</td>
</tr>
<tr>
<td style="width:595px;height:35px;">
<p dir="RTL"><strong>بحث و نتیجه­ گیری</strong>: هر چند مراکز چاپ و تکثیر نمی توانند بعنوان یک کانون جدی انتشار آلاینده ها برای سایر اماکن عمومی اطراف خود باشند، اما آلاینده های حاصل از آنها بخصوص آلاینده <span dir="LTR">O<sub>3</sub></span> می تواند سلامت کارکنان این مراکز را تهدید نماید.</p>
</td>
</tr>
</tbody>
</table>
<div style="clear:both;"></div>
<p><strong><em>Background :</em></strong> Given the large amount of gaseous and aerosol pollutants produced by the printing press industry, the indoor and outdoor air quality of such centers in Khorramabad, Iran was assessed.</p>
<p><strong><em>Methods and Materials: </em></strong>In a descriptive study, five gaseous pollutants from among criteria air pollutants (CO, NO, NO<sub>2</sub>, SO<sub>2</sub>, O<sub>3</sub>) and volatile organic compounds (VOCs) were measured. Overall, 360 samples were taken from the indoor and outdoor air of printing press centers during the two seasons of summer and winter. In addition to the direct reading sampling method, environmental sampling was also conducted. In the direct reading method, the environmental analyzer device was used to measure criteria gaseous pollutants and the phocheck5000 device was used to measure the VOCs. In the sampling by environmental pumps, SKC activated carbon absorbent tubes were used randomly/continuously during the work hours and periodically for all centers. The samples were prepared using a carbon disulfide solution and were analyzed using a gas chromatograph device. Statistical t-tests were used to analyze the results.</p>
<p><strong><em>Results:</em></strong> The results of the study demonstrated that, the concentrations of the all of the criteria pollutants except for the CO gas and, among the VOCs, the concentrations of benzene and toluene in the air of the printing press centers was higher than the standards set by the EPA for indoor areas. Further, there was a significant difference between the concentrations of benzene and toluene during the summer and winder seasons (p<0.05). In all the measurements carried out in summer and winter, the amount of O<sub>3</sub> was significantly higher inside the printing press centers than that of outdoor areas (p<0.05).</p>
<p><strong><em>Conclusion:</em></strong> Although printing press centers cannot be considered as serious hotspots for the emission of pollutants into public places in urban areas, the pollutants produced in these centers, especially O<sub>3</sub> can jeopardize the health of the employees of these centers.</p>
چاپ و تکثیر, آلاینده های شاخص, ترکیبات آلی فرار.
Printing and Copying, Criteria air pollutants, Volatile organic Compounds.
34
41
http://yafte.lums.ac.ir/browse.php?a_code=A-10-1693-40&slc_lang=fa&sid=1
Rajab
Rashidi
رجب
رشیدی
rashidi.r@lums.ac.ir
7200319475328460014294
7200319475328460014294
Yes
Lorestan University of Medical Sciences
دانشگاه علوم پزشکی لرستان
Mohamad
Alamsian
محمد
الماسیان
7200319475328460014295
7200319475328460014295
No
Lorestan University of Medical Sciences
دانشگاه علوم پزشکی لرستان