<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>scientific magazine yafte</title>
<title_fa>مجله علمی پژوهشی یافته</title_fa>
<short_title>yafte</short_title>
<subject>Medical Sciences</subject>
<web_url>http://yafte.lums.ac.ir</web_url>
<journal_hbi_system_id>72</journal_hbi_system_id>
<journal_hbi_system_user>journal72</journal_hbi_system_user>
<journal_id_issn>1563-0773</journal_id_issn>
<journal_id_issn_online>2981-0779</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034/Yafteh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1382</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2004</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>5</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه عوارض ناشی از آیودی های cuT 380 Aو cu safe 300 در سه ماهه اول بعد از جایگذاری</title_fa>
	<title> Comparison of complications result from CU-T 380 A and CU Safe 300 IUDs three months after insertion</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي اصیل</content_type_fa>
	<content_type>Original Research </content_type>
	<abstract_fa>مقدمه :.مطالعات نشان داده است میزان بروز عوارض در انواع مختلف آیودی متفاوت است و هر چه اندازه آیو دی کوچکتر باشد، عوارضی مثل خونریزی و درد کمتر است. هدف از انجام این مطالعه تعیین و مقایسه عوارضی مثل خونریزی،درد و دفع خود به خود آیودی در استفاده کنندگان آیودی های cuT 380A و cu Safe 300 در سه ماهه اول بعد از جایگذاری بود.
مواد و روشها : پژوهش حاضر یک کارآزمایی بالینی است که بر روی کلیه خانم های متقاضی آیو دی مراجعه کننده (243) به مراکز بهداشتی درمانی شهر خرم آباد طی 9 ماه انجام شد. نمونه گیری به صورت تصادفی ساده انجام شد.اطلاعات از طریق پرسشنامه و با استفاده از مصاحبه و مشاهده جمع آوری گردید.
یافته ها : نتایج حاصل از پژوهش نشان داد طی سه ماه شدت و شیوع درد و دفع خودبخود در گروه cuT 380 A بیشتر از گروه cu safe 300 بود و با استفاده از آزمون های آماری تفاوت معنی داری بین دو گروه مشاهده شد؛ ولی از نظر شدت خونریزی بین دو گروه تفاوت معنی داری مشاهده نشد.
نتیجه گیری : :مطالعه حاضر نشان می دهد که آیو دی های جدید(CU Safe 300) که در اندازه ای کوچکتر و سازگار با انقباضات رحم ساخته شده اند، کم عارضه تر بوده و بسیار مورد پذیرش استفاده کنندگان واقع شده اند بنابراین توصیه می شود در صورت امکان استفاده از این آیودی جدید نیز در مراکز بهداشتی درمانی گسترش یابد.
</abstract_fa>
	<abstract>Introduction: Series studies have shown that complications vary based on the kind of IUD, and the smaller the size of IUD is the less the complications, such as bleeding and pain, will be.
The aim of this study was to determine and to compare complications including bleeding, pain and etc in CU-T 380 A and CU Safe 300 IUDs users, three months after insertion.
Materials and Methods: The present research is a clinical trial study carried out on 243 women demanding for IUD referred to Khorramabad health and treatment centers. Data were gathered using questionnaire and interview.
Findings: Results showed that severity and prevalence of pelvic pain and spontaneously remove of IUD were more in CU-T 380 A group than that of CU safe 300 group. Statistical test showed significant differences between these two groups, but no significant difference was observed from view point of bleeding.
Conclusion: This study shows that new IUDs (CU Safe 300) which are smaller in size have less complications and are in much demand by women, so utilizing this new IUD in health and treatment centers is suggested.
</abstract>
	<keyword_fa>عوارض آیودی، cu Safe 300، cuT 380A</keyword_fa>
	<keyword>CU-T 380 A, CU Safe 300, IUD complications</keyword>
	<start_page>53</start_page>
	<end_page>57</end_page>
	<web_url>http://yafte.lums.ac.ir/browse.php?a_code=A-10-1-287&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>farahnaz</first_name>
	<middle_name></middle_name>
	<last_name>Changavi</last_name>
	<suffix></suffix>
	<first_name_fa>فرحناز </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>چنگاوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>720031947532846005733</code>
	<orcid>720031947532846005733</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>fatemeh</first_name>
	<middle_name></middle_name>
	<last_name>Janani</last_name>
	<suffix></suffix>
	<first_name_fa>فاطمه </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جنانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>720031947532846005734</code>
	<orcid>720031947532846005734</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>mohammad javad</first_name>
	<middle_name></middle_name>
	<last_name>tarrahi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد جواد </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طراحی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>720031947532846005735</code>
	<orcid>720031947532846005735</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
